Using Core
Samples to Measure Hydrogeologic Properties of Bedrock Aquifers
The
Department of Earth Resources at Colorado State University is responsible
for taking Kiowa core samples and measuring the hydrogeologic properties,
such as porosity, specific yield, and hydraulic conductivity in
the laboratory. The following describes how each laboratory analysis
is performed.
1.)
Porosity is defined as the amount of void space in a rock. The percent
porosity can be expressed as percent
porosity = (volume of void space/total volume of rock) x 100
When
the sample is saturated, this void space is filled with water. Porosity
can be measured in the lab by completely saturating the core sample
with water, weighing it, and then completely drying the sample and
weighing it. The difference in weight is due to the water loss,
which is equal to the volume of pore space. Typical porosity values
for sedimentary rocks (of which the Denver Basin is composed) include:
24-36% Coarse Gravel
31-46% Coarse Sand
34-60% Clay
2.)
Specific Yield is defined as the amount of water that can be removed
from the saturated pores by draining due to gravity. We have chosen
to use a pressure-plate apparatus to measure this property. It is
very important to have a fully saturated sample. Think of the rock
sample as a wet sponge. By applying pressure (squeezing) to the
sponge, the water is being driven out of the sponge. With increasing
pressure, more water is forced out of the sponge. Since is it relatively
difficult to squeeze water from a rock, we use a pressure chamber
(which resembles a pressure cooker). Pressure is increased stepwise
until no more water can be drained from the core. The amount of
water that will not drain from the pores is called the specific
retention. The amount of water that is removed as a function of
the amount of pressure applied to the rock can be used to calculate
the specific yield.
3.)
Hydraulic Conductivity is a measurement of the ease with which water
moves through the pores of a rock. This is sometimes referred to
as permeability. This is different than porosity. For example, clay
materials hold a large amount of water (large porosity) but the
water does not flow through the material easily (low hydraulic conductivity).
Hydraulic conductivity can be measured using a permeameter. (See
Figure No.1) A permeameter is typically a cylindrical tube containing
the rock sample. Water is allowed to enter the tube, and the rate
of water exiting the permeameter is measured. Using Darcy's Law,
a mathematical expression developed by a French engineer named Henry
Darcy, the hydraulic conductivity can be calculated.
These
tests are fairly easy to perform and provide important information
pertaining to the amount of water stored in bedrock aquifers. Removing
too much water from an unconfined aquifer will result in the eventual
drawdown of an aquifer. Drawdown involves lowering the water table.
If the water table becomes too low, water wells go dry. If a confined
aquifer is partially drained, it becomes harder for water wells
to pump the remaining water. (See Figure No. 2 for the difference
between a confined and an unconfined aquifer.) This has happened
in some areas of the Denver Basin. Recharge is the water that the
aquifer receives from rainwater or seepage from an overlying aquifer.
Recharge rates can be very slow. Knowing more about the Denver Basin
aquifers will allow our local decision-makers to make educated decisions
regarding the amount of water that is pumped from the aquifers in
order to minimize the effects of drawdown on the aquifers.
*Definitions
and information were cited from C.W. Fetter's (1994) textbook Applied
Hydrogeology.
Back
to top
|